Flicker
Caused by
Rapidly switching loads
Effects
Unstable load operation · Lighting flicker · Equipment maloperation
Power Quality
Energy-efficient power electronics improves the load side and pollutes the supply. That pollution then affects the equipment itself and everything else on the same supply. We have decades of experience identifying, quantifying and solving these problems across all industries and voltage levels.
Diagnosis
Find the symptom you are seeing and the equipment that corrects it.
Caused by
Rapidly switching loads
Effects
Unstable load operation · Lighting flicker · Equipment maloperation
Caused by
Motor drives · LED lighting · IT equipment · Welding equipment
Effects
Motor overheating · Cable overheating · Accelerated ageing · Premature failure · Increased costs
Caused by
Inductive loads · AC and DC motors · Welding equipment
Effects
Increased supply demand · Overloaded supplies · Increased charges
Caused by
Load fluctuations · Poor power factor · Weak supply network
Effects
Unstable load operation · Load maloperation · Nuisance tripping
Caused by
Unbalanced loads · Malfunctioning equipment
Effects
Negative sequence voltages · Increased losses · Equipment overtemperature
Solid state
Semiconductor-based compensation gives the best performance, response time and control, and does not resonate with a distorted supply.

AFQm
Semiconductor-based harmonic current and reactive power compensation, from 30 A to thousands of amps.
Typical ratings

AFQs
Silicon carbide wall-mounting active harmonic filter with reduced losses and smaller dimensions.
Typical ratings

MV-AHF
AFQm with a step-up transformer for medium voltage networks, to 10 MVAr equivalent.
Typical ratings

SVGm
Fast reactive power compensation from 30 kVAr to MVAr, in wall, rack and cabinet formats.
Typical ratings

HVC
Combines capacitor banks with an SVG or AHF so bulk correction is cheap and the fast correction is accurate.
Typical ratings
Capacitor based
Proven technology, and a good solution when correctly specified. Standard PFC is rarely appropriate today given rising distortion levels; detuned equipment is almost universally adopted instead.

Optim-FRE
Thyristor-switched detuned power factor correction, responding up to 100 times faster than contactor switching.
Typical ratings

Optim-FR
Detuned power factor correction, robust on supplies with low to moderate distortion.
Typical ratings

Optim
Standard contactor-switched power factor correction, for clean supplies only.
Typical ratings
Get in touch
That is the usual starting point. We measure first, then specify — so you buy the equipment the supply actually needs.